The subsystem of the horizontal zone of the integrated cabling in the server room includes two subsystems of voice system and data system, and the design of the subsystem in this zone should adopt Category 6 cabling products (such as Category 6 unshielded network patch cords, etc.) to realize the data transmission network with 1000 Mbps transmission rate, and in addition, the media of data points and voice points should be consistent in order to realize the flexible interchangeability of data points and voice points. At the same time, in order to make the integrated wiring of the server room highly reliable, the twisted pair cable with high redundancy and strong anti-interference can be used in the integrated wiring of the horizontal area subsystem.
The design of the vertical trunk subsystem of the server room is combined with the demand of voice communication in the comprehensive cabling project of the server room, and the vertical trunk voice system should adopt three types of large log UTP cables, with each voice point corresponding to a pair of trunk cables, while considering the 1:1.1 trunk redundancy. In addition, the data trunk of the vertical trunk subsystem should use six-core indoor multimode 10 Gigabit fiber.
The management area subsystem of the server room includes wiring room configuration, wiring cabinet, copper wiring frame, optical wiring frame and management patch cord. Among them, the wiring room needs to install network cabinet equipment; wiring cabinet network equipment should follow the standard 19-inch size, so that the later maintenance management in each floor choose to install vertical cabinets; copper wiring frame is connected to the vertical trunk cable and voice level wiring frame, should be configured to cross-connect wiring frame; wiring frame can choose twenty-four-port category 6 shielded unshielded type, in order to quickly connect with network equipment; fiber optic wiring frame is also Standardized 19-inch fiber optic distribution frame should be used to connect multimode indoor fiber; LC duplex dual-core fiber optic patch cord should be used for the fiber optic patch cord in the management patch cord, but Category 6 network patch cord should be used for the data part and voice part of the network patch cord.
The equipment room subsystem design of the server room is combined with the comprehensive cabling design specification of the server room, and the equipment room needs to be set up in the center of the building to manage the comprehensive cabling network in the whole building, which can effectively reduce the amount of backbone cables in the comprehensive cabling inside the building. The equipment room subsystem of the server room includes wiring closet, copper wiring frame, optical wiring frame and management room patch cord. Among them, the wiring closet should adopt standardized 19-inch equipment for later maintenance and management; copper wiring frame connects voice module, total distribution frame and vertical trunk cable distribution frame among voice center equipment, and the total distribution frame is supplied by telecom bureau, so Cat3 voice distribution frame and network distribution frame are selected; optical wiring frame also adopts 19-inch fiber optic distribution frame, which can connect multi-mode indoor fiber; fiber optic patch cord in the management booth jumper LC duplex dual-core fiber patch cord is used, but the network patch cord of data part and voice part should be used as Class VI network patch cord.