As the construction of data center server room carries the transmission of the whole communication data, the comprehensive wiring of the server room is very important. In the past, the data center did not have high requirements for the comprehensive wiring of the server room, as long as the equipment can operate normally, but with the development of high performance and high density of the data center, the scale of the server room is getting bigger and bigger, and the comprehensive wiring structure of the server room is also getting more and more complicated, so that users can build a neat and beautiful, green and energy-saving server room.
What are the integrated cabling structures in the server room?
The integrated cabling structure of the server room generally requires short cabling distance, neatness and orderly arrangement. At present, the integrated cabling structure of the server room mainly has two types of structure: "field" and "well", of which "field" structure is more suitable for the layout of the ring-shaped server room. The "well" shape is more applicable to the vertical and horizontal layout of the server room, and both cabling structures can be wired in two positions on the ceiling and under the floor.
As the central nerve of the data center, it is related to the operation status of the whole network. How should the integrated cabling in the server room be designed to meet the demand for high speed and high performance in the data center?
The work area subsystem design of the server room should be combined with the actual situation in the building. The work area adopts six types of information modules, specifies the needs of each equipment in the work area, estimates the information points, and uses the layout and installation of servers and terminal equipment in the server room.
The information point of the server room work area subsystem is designed as cabinet type equipment, including server cabinets, network equipment, etc. The service equipment is uniformly installed in the cabinets. Five cabinets need to be installed in this work area subsystem: the first cabinet installs firewall, next generation firewall, SSLVPN, core switch, access switch, cloud service switch, alarm module, embedded monitoring and management server, power distribution monitoring and detection, and UPS monitoring and wireless controllers; the second cabinet installs servers, KVM switches, blade servers, cloud graphics cards, voice boards, UPS and other equipment; the third cabinet installs keyboards and mice monitors, KVM switches, servers and other equipment; the fourth cabinet installs tape libraries, storage devices, fiber optic switches, UPS and other equipment; the fifth cabinet installs monitors keyboards and mice, servers, firewalls, switches and other equipment; in addition, the environmental monitoring system is installed with precision air conditioning, temperature and humidity monitoring, precision air conditioning monitoring and ultrasonic humidifier.
In the design of information points, a certain amount of expansion space should be reserved for the expansion of the comprehensive cabling system in the server room.